Description: Main motor lock The machine does not detect motor lock signal for 250 ms during motor's operating. The machine does not detect motor lock signal for 1 second at rotating the main motor.
Causes: • An obstruction has blocked operation of the main motor • Main motor harness loose or broken • Main motor or main motor driver board defective