Mã lỗi 547 — Ricoh M078 Aficio Pro C720 AGL-P1

Code: 547

Description: Zero cross error • The zero cross signal is detected once in the three zero cross signal detections even though the heater relay is off when turning on the main power. • The detection error occurs twice or more in the 10 zero cross signal detections. This error is defined when the detected zero cross signal is less than 44.
Causes: • Defective fusing relay • Defective fusing relay circuit • Shorted +24V fuse on the PSU • Unstable power supply • Defective breaker or breaker off • Defective FIB (+6VGINT off) • Defective AC drive board (Defective power relay) • Defective IOB 2
Remedy: 1. Check the power supply source. 2. Make sure that the breaker is turned on. 3. Replace the breaker if the breaker is not turned on. 4. Replace the FIB if +6VGINT (CN337-1 on IOB 2) is OFF. 5. Replace the AC drive board. 6. Replace the IOB 2. 7. Replace the +24V fuse on the PSU. 8. Replace the PSU