Mã lỗi 796-32 — Ricoh M078 Aficio Pro C720 AGL-P1

Code: 796-32

Description: Sub Grip Size HP Sensor (S38) Error PB (D391)
Causes: The sub grip size HP sensor did not go ON within the prescribed time after the sub grip size motor turned on for horizontal adjustment to the paper size. -or- The sub grip size HP sensor was already OFF when the sub grip size horizontal adjustment started (from the open to closed position). • Sub Grip Size Motor (S19) defective • Sub Grip Size HP Sensor (S38) defective • Motor or sensor connector loose, broken, defective The sub grip size HP sensor did not go OFF within the prescribed time after the sub grip size motor turned on to close sub grippers for horizontal adjustment of the paper size. -or- The sub grip size HP sensor was already ON when the sub grip size horizontal adjustment started (from the close to open position). • Sub Grip Size Motor (S19) defective • Sub Grip Size HP Sensor (S38) defective • Motor or sensor connector loose, broken, defective
Remedy: