Code: 361-02
Description: TD sensor (Vt high) error 1: C
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3-020-002 for twenty counts. The [Vt - Vtref] value of the black, cyan, magenta, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3-020-001.
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3-020-002 for twenty counts. The [Vt - Vtref] value of the black, cyan, magenta, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3-020-001.
Causes: A TD sensor-related part is faulty. A TD sensor-related part's connection is loose. Toner density error.
Remedy: • Turn the main power switch off and then back on. • Replace the AIT (development unit).