Code: 498
Description: Temperature and humidity sensor error 2
Thermal sensor output error: If the output value is 0.5 V or lower or 3.0 V or higher, it is judged as a sensor error and the presumptive temperature, 23C, is applied. Humidity sensor output error: If the output value is 2.4V or higher, it is judged as a sensor error and the presumptive humidity, 50 % RH, is applied. If a sensor error is judged to have occurred to the thermal sensor or humidity sensor three times consecutively, the machine issues SC498-00. * However, if the power is switched off and then back on, the machine resumes its attempt to use the sensor. * If the thermal sensor or humidity sensor remains capable of normal operation even after the SC is issued, the capable sensor will keep operating.
Thermal sensor output error: If the output value is 0.5 V or lower or 3.0 V or higher, it is judged as a sensor error and the presumptive temperature, 23C, is applied. Humidity sensor output error: If the output value is 2.4V or higher, it is judged as a sensor error and the presumptive humidity, 50 % RH, is applied. If a sensor error is judged to have occurred to the thermal sensor or humidity sensor three times consecutively, the machine issues SC498-00. * However, if the power is switched off and then back on, the machine resumes its attempt to use the sensor. * If the thermal sensor or humidity sensor remains capable of normal operation even after the SC is issued, the capable sensor will keep operating.
Causes: Loose connection/harness disconnected. Defective sensor.
Remedy: • Reconnect to the connector. • Check the harness.