Code: 543
Description: High temperature error (Soft)
Causes: • The detected temperature stays at 235°C for 1 second, and this consecutively occurs 10 times.
Remedy: • Defective Main board • Defective PSU 1. Replace the Main board 2. Replace the PSU • Execute "Fuser SC Reset" to recover the machine after completing the recovery procedure. Otherwise, the machine continues to issue this SC code and cannot be operated.