Code: 998
Description: Application start error No applications start within 60 seconds after the power is turned on.
Causes: • Loose connection of RAM-DIMM, ROM-DIMM • Defective controller • Software problem
Remedy: 1. Check if the DIMM memory is correctly connected. 2. Reinstall the controller system firmware. 3. Replace the controller.If a problem always occurs in a specific condition (for example. printer driver setting, image file), the problem may be caused by a software error. In this case, the following data and information needs to be sent back to your product specialist. Please understand that it may take some time to get a reply on how to solve the problem, because in some cases the design staff in Japan must analyze the data. • Symptom / Possible Causes / Action taken • Summary sheet (SP mode "Printer SP", SP1-004 [Print Summary]) • SMC - All (SP5-990-001) • SMC - Logging (SP5-990-004) • Printer driver settings used when the problem occurs • All data displayed on the screen (SC code, error code, and program address where the problem is logged.) • Image file which causes the problem, if possible