Code: 750
Description: Output tray motor error
The 1st detection failure issues a jam error, and the 2nd failure issues this SC code. • The machine does not detect correctly the position of the output tray when the output tray motor starts to rotate.
The 1st detection failure issues a jam error, and the 2nd failure issues this SC code. • The machine does not detect correctly the position of the output tray when the output tray motor starts to rotate.
Causes: • Output tray motor defective • Loose connection • Motor overload • Upper limit sensor and/ or stack near limit sensor defective