Code: 2F2F
Display: Hardware error. 03800500-2F2F Turn off printer, wait, then turn on again.
Description: Non-ejection detection error As a result of nozzle checking made by the head management sensor unit: 1. All 640 nozzles in a nozzle line are nondischarging. 2. At least 50 nozzles have been found mismatched in a nozzle line of 640 nozzles since the last session of detection.
Remedy: 1. Check whether any foreign matter such as paper slip exists on the head management sensor optical axis. 2. Light interception due to ink accumulation.-> Remove the ink/ Replace the unit. 3. Check the head management sensor's connector connection 4. If Service mode nozzle check pattern printing is no problem, replace the head management sensor unit. Reference 1) As for the detection condition 1. above, in the iPF650/750, iPF6300/6350, and iPF8300 series or later, the error codes are broken up into 2F40,2F41,2F42,2F43,2F44, and 2F47 depending on the non-ejection conditions. Reference 2) Error 2F2F,2F40,2F41,2F42,2F43,2F44, and 2F47 are detected in the following order. 1. Determines signal level (2F47) of head management sensor 2. Determines complete non-ejection of all colors (2F40) 3. Determines multiple mismatches (2F2F) 4. Determines complete non-ejection of a single color (2F41) 5. Determines complete non-ejection of one line (2F42) 6. Determines complete non-ejection of 640 nozzles (2F43) 7. Determines non-ejection of more than 320 nozzles (2F44) Reference 3) The amount of change (between non-ejecting and ejecting nozzle counts) from the last session of nozzle checking is defined as the amount of mismatch.