Code: E001-0001
Description: Fixing Assembly high temperature error (hardware detection)
The hardware circuit detected overheating of the Fixing Main Thermistor (THM1) or Fixing Sub Thermistor (THM2) for 30msec or longer on end.
The hardware circuit detected overheating of the Fixing Main Thermistor (THM1) or Fixing Sub Thermistor (THM2) for 30msec or longer on end.
Remedy: 1. Perform the following to clear the error: COPIER > FUNCTION > CLEAR > ERR in the Service Mode; then, turn the power switch to OFF and then ON.
2. Check the connection of the Fixing Assembly. (Connection error of the Drawer, connector disconnection, open circuit)
3. Check the connection between the AC Driver PCB (PCB4) and Fixing Assembly.
4. Replace the Fixing Assembly.
5. Replace the AC Driver PCB (PCB4).
6. Replace the DC Controller PCB (PCB1).
2. Check the connection of the Fixing Assembly. (Connection error of the Drawer, connector disconnection, open circuit)
3. Check the connection between the AC Driver PCB (PCB4) and Fixing Assembly.
4. Replace the Fixing Assembly.
5. Replace the AC Driver PCB (PCB4).
6. Replace the DC Controller PCB (PCB1).