Code: E002-0000
Description: Fixing Assembly temperature rise error
1. The Fixing Main Thermistor (THM1) detected the temperature of lower than 115 degrees C for 400msec or longer on end 6.0 seconds later after detecting 100 degrees C.
2. The Fixing Main Thermistor (THM1) detected the temperature of lower than 150 degrees C for 400msec or longer on end 6.0 seconds later after detecting 140 degrees C.
1. The Fixing Main Thermistor (THM1) detected the temperature of lower than 115 degrees C for 400msec or longer on end 6.0 seconds later after detecting 100 degrees C.
2. The Fixing Main Thermistor (THM1) detected the temperature of lower than 150 degrees C for 400msec or longer on end 6.0 seconds later after detecting 140 degrees C.
Remedy: 1. Perform the following to clear the error: COPIER > FUNCTION > CLEAR > ERR in the Service Mode; then, turn the power switch to OFF and then ON.
2. Check the connection of the Fixing Assembly. (Connection error of the Drawer, connector disconnection, open circuit)
3. Check the connection between the AC Driver PCB (PCB4) and Fixing Assembly.
4. Replace the Fixing Assembly.
5. Replace the AC Driver PCB (PCB4).
6. Replace the DC Controller PCB (PCB1).
2. Check the connection of the Fixing Assembly. (Connection error of the Drawer, connector disconnection, open circuit)
3. Check the connection between the AC Driver PCB (PCB4) and Fixing Assembly.
4. Replace the Fixing Assembly.
5. Replace the AC Driver PCB (PCB4).
6. Replace the DC Controller PCB (PCB1).