Code: 542
Description: Fusing temperature warm-up error
One of the following occurred:
• After power on, or after closing the front door, the hot roller does not reach the 100°C control temperature within 25 s.
• 5 sec. after temperature rise started, temperature remained below 21°C after 5 samplings.
• Fusing unit did not attain reload temperature within 48 sec. of the start of fusing temperature control.
One of the following occurred:
• After power on, or after closing the front door, the hot roller does not reach the 100°C control temperature within 25 s.
• 5 sec. after temperature rise started, temperature remained below 21°C after 5 samplings.
• Fusing unit did not attain reload temperature within 48 sec. of the start of fusing temperature control.
Causes: • Fusing lamp disconnected
• Thermistor warped, out of position
• Thermostat not operating
• Thermistor warped, out of position
• Thermostat not operating