Code: 770
Description: Cover interposer tray bottom plate motor error
• After the motor starts to raise the bottom plate, the bottom plate position sensor does not detect the plate at the specified time (3 s).
• After the motor starts to lower the bottom plate, the bottom plate HP sensor does not detect the bottom plate
• After the motor starts to raise the bottom plate, the bottom plate position sensor does not detect the plate at the specified time (3 s).
• After the motor starts to lower the bottom plate, the bottom plate HP sensor does not detect the bottom plate
Causes: • Bottom plate position sensor, disconnected, defective
• Bottom plate HP sensor disconnected, defective
• Bottom plate HP sensor disconnected, defective