Code: 025-0001-05
Description: Failure of the Bottle Motor (M17)
Causes: The Bottle Motor (M17) lock signal does not indicate a locked state a specific period of time after the Bottle Motor (M17) has been started. * The same condition is detected after the error retry is performed.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J324,J9324) to the Bottle Motor (M17/ J41) - Bottle Motor (M17) - DC Controller PCB (UN2) - All-night Power Supply PCB (UN1) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the DC Controller PCB. 3.Replace the All-night Power Supply PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES