Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 000-0001-05 — Canon iR Advance 4535i

Code: 000-0001-05

Description: Fixing temperature abnormal rise
Causes: The temperature detected by the main thermistor does not rise to the specified value during startup control.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J307) to the Fixing Main Thermistor (TH1/ J707) - Fixing Main Thermistor (TH1) - Fixing Unit - DC Controller PCB (UN2) [Remedy] 1.Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR; and then turn OFF and then ON the power. 2.Check/replace the harness and connector between the DC Controller PCB and the Fixing Main Thermistor. 3.Replace the Fixing Main Thermistor (Film Unit). 4.Replace the Fixing Unit. 5.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES