Code: 110-0003-05
Description: Failure of the Polygon Motor (M11)
Causes: The Polygon Motor (M11) speed lock signal does not indicate a locked state for 6.5 sec. after a switchover is made from low to normal speed or for 8 sec. after a switchover is made from normal to low speed. * The same condition is detected after the error retry is performed.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J324,J9324) to the Laser Scanner Unit (J745/J744/J9744/J602/J9602) - Laser Scanner Unit - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the Laser Scanner Unit. 3.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES