Code: 197-0000-05
Description: Error in communication of Laser Driver PCB Communication time out error between DC Controller PCB and Main Controller PCB 2
Causes: Communication error with image PCB (For factory) Communication time out error between DC Controller PCB and Main Controller PCB 2
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J324,J9324) to the Laser Scanner Unit (J745/J744/J9744/J602/J9602) - Harness connecting from the Main Controller PCB 2 (UN14/J7201) to the Laser Scanner Unit (J601) - Laser Scanner Unit - Main Controller PCB 2 (UN14) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the Laser Scanner Unit. 3.Replace the Main Controller PCB 2. 4.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES