Mã lỗi 227-0101-04 — Canon iR Advance 4535i

Code: 227-0101-04

Description: Power supply error
Causes: The DADF Driver PCB did not detect 24 V when the main power was turned ON.
Remedy: [Related parts] R1.00 - Harness between the Reader Controller PCB (UN_BO1/J104) and the DADF Driver PCB (PCB1/ J402) - Harness between the Reader Controller PCB (UN_BO1/J101) and the AC Driver PCB (UN30/ J118) - Harness between the AC Driver PCB (UN30/J112) and the 12V/24V Power Supply PCB (UN5/ CN52) - Reader Controller PCB (UN_BO1) - DADF Driver PCB (PCB1) - AC Driver PCB (UN30) - 12V/24V Power Supply PCB (UN5) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - When an error is detected, conduction of 24 V is stopped. At power check, check if 24 V is conducted or rated voltage is output by repeating power cycling of the machine. - Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES