Mã lỗi 002-0000-05 — Canon iR Advance 4545i

Code: 002-0000-05

Description: Fixing unit temperature insufficient rise
Causes: 1.The reading of the main thermistor is less than 115 deg C continuously for 400 msec 2.5 sec after it has indicated 100 deg C. 2.The reading of the main thermistor is less than 150 deg C continuously for 400 msec 1.3 sec after it has indicated 140 deg C.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J307) to the Fixing Main Thermistor (TH1/ J707) - Fixing Main Thermistor (TH1) - Fixing Unit - DC Controller PCB (UN2) [Remedy] 1.Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR; and then turn OFF and then ON the power. 2.Check/replace the harness and connector between the DC Controller PCB and the Fixing Main Thermistor. 3.Replace the Fixing Main Thermistor (Film Unit). 4.Replace the Fixing Unit. 5.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES