Code: 010-0002-05
Description: Unstable rotation of the Main Motor (M1)
Causes: During motor rotation, detection is executed every 100 msec; however, the drive signal is absent 5 times in sequence.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J309) to the Main Motor (M1/J137) - Main Motor (M1) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES