Mã lỗi 743-0000-05 — Canon iR Advance 4551i

Code: 743-0000-05

Description: DDI communication error
Causes: The Reader Controller PCB detected the communication error between the Main Controller PCB and the Reader Controller PCB.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2) to the Reader Controller PCB (UN_B01). - Reader Controller PCB (UN_B01) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the Reader Controller PCB. 3.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES