Mã lỗi 806-0000-05 — Canon iR Advance 4551i

Code: 806-0000-05

Description: Failure of the Main Body Cooling Fan (FM6)
Causes: When lock signal is detected for 5 sec while the Main Body Cooling Fan (FM6) is stopped. *The same condition is detected after the error retry is performed.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J337) to the Main Body Cooling Fan (FM6/ J441) - Main Body Cooling Fan (FM6) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES