Description: Fixing Assembly low temperature error
The detected temperature of the Fixing Main Thermistor (THM1) failed to reach the specified temperature at the fixing start control.
Remedy: 1. Perform the following to clear the error: COPIER > FUNCTION > CLEAR > ERR in the Service Mode; then, turn the power switch to OFF and then ON.
2. Check the connection of the Fixing Assembly. (Connection error of the Drawer, connector disconnection, open circuit)
3. Check the connection between the AC Driver PCB (PCB4) and Fixing Assembly.
4. Replace the Fixing Assembly.
5. Replace the AC Driver PCB (PCB4).
6. Replace the DC Controller PCB (PCB1).