Description: Coin vendor error
IPC error at coin vendor operation
- Open circuit of IPC, unable to recover the IPC communication
- When open circuit of the pickup/delivery signal cable is detected
- Invalid connection is detected
Remedy: Check cable connection between the charging management equipment and the host machine.
While the charging management equipment is connected for operation, clear the error in the case of switching to the operation without the charging management equipment.
(To prevent a misuse by removing the charging management equipment, this error code is displayed.)