Code: SC351
Description: ID sensor error 2
One of the following ID sensor output voltages was detected twice consecutively when checking the ID sensor pattern. 1) Vsg< 2.5V 2) Vsg = 0V 3) The ID sensor output voltage is 5.0V and the PWM signal input to the ID sensor is 0 when checking the ID sensor pattern
One of the following ID sensor output voltages was detected twice consecutively when checking the ID sensor pattern. 1) Vsg< 2.5V 2) Vsg = 0V 3) The ID sensor output voltage is 5.0V and the PWM signal input to the ID sensor is 0 when checking the ID sensor pattern
Causes: • ID sensor defective • ID sensor connector defective • Poor ID sensor connector connection • I/O board (IOB) defective • Charge or development power pack defective • Dirty ID sensor • Defect at the ID sensor pattern writing area of the drum