Code: E017-0002
Description: ETB engagement error
Engagement of the ETB is not completed within the specified period of time.
Engagement of the ETB is not completed within the specified period of time.
Remedy: 1. Check the connection of the ETB Disengage Sensor (PS55). Sensor side: J2100, J3270, PCB side: J343 (Duplex Driver PCB (PCB4)) 2. Check the connection of the Duplex Feed Left Motor (M19). Motor side: J2107, J3044 (relay), PCB side: J330 (Duplex Driver PCB (PCB4)) 3. Replace the ETB Engage Sensor (PS55). 4. Replace the Duplex Feed Left Motor (M19). 5. Replace the Duplex Driver PCB (PCB4). 6. Replace the DC Controller PCB (PCB1). NOTE: Check if the Disengagement Cam is stained. If necessary, clean it. Check if the drive system (gear, Motor, one-way) is failed. If necessary, replace it. Check if the link with the Fixing Feed Handle is failed. If necessary, replace it.