Mã lỗi E067-0001 — Canon iR Advance 6065i

Code: E067-0001

Description: Developing high voltage output leak error
The leak detection signal was detected 5 times in a row for every 20 msec.
Remedy: 1. Check the connection between the Main Driver PCB (PCB2) and the High Voltage Unit. Main Driver side: J112, High Voltage Unit side: J3098 2. Check the connection between the Relay PCB (PCB5) and the High Voltage Unit. Relay side: J519, High Voltage Unit side: J3099 3. Replace the Developing Assembly. 4. Check the connection point of the Developing Assembly. If it is soiled, clean it. 5. Check the connection inside of the High Voltage Unit. Check the connection of the High Voltage Unit Relay (J3097) and the Developing High Voltage PCB (J3511). High Voltage Unit Relay (J3099) and Pre-transfer Charging PCB (J3545, J3500, J3510) 6. Replace the Main Driver PCB (PCB2).