Mã lỗi E002-0001 — Canon iR Advance 6075i

Code: E002-0001

Description: Fixing Assembly temperature rise error
• Temperature of the Fixing Main Thermistor (THM1) does not reach 100 degC although 12 seconds have passed since it reached above 70 degC after starting the Fixing Roller temperature control. • Temperature of the Fixing Main Thermistor does not reach 130 degC although 12 seconds have passed since it reached above 100 degC after starting the Fixing Roller temperature control. • Temperature of the Fixing Main Thermistor does not reach 150 degC although 20 seconds have passed since it reached above 130 degC after starting the Fixing Roller temperature conrtol.
Remedy: 1. Check the connection of the Fixing Main Thermistor (THM1). -> Replace the Fixing Main Thermistor Unit. 2. Check the installation of the Fixing Main Thermistor. -> Replace the Fixing Upper Unit. 3. Replace the Fixing Power Supply PCB (PCB10). 4. Replace the Main Driver PCB (PCB2). 5. Replace the DC Controller PCB (PCB1). 6. Replace the Relay PCB (PCB5).