Mã lỗi E068-0001 — Canon iR Advance 6255

Code: E068-0001

Description: Pre-transfer charging high voltage output leak error
The leak detection signal was detected 5 times in a row for every 20 msec.
Remedy: 1. Check the connection between the Main Driver PCB (PCB2) and the High Voltage Unit. Main Driver side: J112, High Voltage Unit side: J3098 2. Check the connection between the Relay PCB (PCB5) and the High Voltage Unit. Relay side: J519, High Voltage Unit side: J3099 3. Replace the Pre-transfer Charging Assembly. 4. Check the connection inside of the High Voltage Unit. Check the connection of the High Voltage Unit Relay (J3098) and the Transfer High Voltage PCB (J3544). Check the connection of the High Voltage Unit Relay (J3099) and the Pre-transfer Charging PCB (J3545, J3500) 5. Replace the Main Driver PCB (PCB2). 6. Replace the Pre-transfer High Voltage Connector (FM4- 1007). 7. Replace the Pre-transfer Transformer (Post Charging Trance) of the High Voltage Unit.