Code: E060-0001
Description: Primary Charging Shutter HP open error
The Primary Charging Shutter Sensor (PS94) detects that the shutter is opened although it is moved to the close position.
The Primary Charging Shutter Sensor (PS94) detects that the shutter is opened although it is moved to the close position.
Remedy: 1. Check the position of the Primary Charging Shutter and the Cleaning Pad. 1-A. In the case that the Primary Charging Shutter and the Cleaning Pad fail to operate (stopped at HP at front side) 1-A-1. Check the connection of the Primary Charging Wire Cleaning Motor (M6). Motor side: J3017, J3060 (iR-ADV 8xxx)/J3160 (iRADV 6xxx) (relay), PCB side: J3177 (relay), J107 (Main Driver PCB (PCB2)) 1-A-2. Replace the Primary Charging Wire Cleaning Motor (M6). 1-B. In the case that the Primary Charging Shutter and the Cleaning Pad are stopped at rear side (close operation position) 1-B-1. Check the connection of the Primary Charging Shutter Sensor (PS94). Sensor side: J2029, J3089 (relay), PCB side: J3088 (relay), J114 (Main Driver PCB (PCB2)) 1-B-2. Replace the Primary Charging Shutter Sensor (PS94). 1-C. In the case that the Primary Charging Shutter and the Cleaning Pad are stopped along the way 1-C-1. Check the loosening of screw on the Slider Pin and abrasion of the pin. Tighten the screw or replace the Slider Pin. 1-C-2. Replace the Primary Charging Assembly. 1-D. In the case that the Primary Charging Shutter stops at front side and the Cleaning Pad moves to rear side 1-D-1. Check if the Shutter Mounting Plate is deformed. If so, replace the Shutter Unit. 1-D-2. Check the loosening of screw on the Slider Pin and abrasion of the pin. Tighten the screw or replace the Slider Pin. 1-D-3. Replace the Primary Charging Assembly. 2. Replace the Main Driver PCB (PCB2). 3. Replace the DC Controller PCB (PCB1).