Mã lỗi E065-0001 — Canon iR Advance 6275

Code: E065-0001

Description: Primary charging/grid high voltage output leak error
The leak detection signal was detected 5 times in a row for every 20 msec.
Remedy: 1. Check the connection between the Main Driver PCB (PCB2) and the High Voltage Unit. Main Driver side: J111, High Voltage Unit side: J3097 2. Check the connection between the Relay PCB (PCB5) and the High Voltage Unit. Relay side: J519, High Voltage Unit side: J3099 3. Replace the Primary Charging Assembly. 4. Check the connection inside of the High Voltage Unit. High Voltage Unit Relay (J3097) and Primary Charging High Voltage PCB (PCB11) (J3501) High Voltage Unit relay (J3099) and Pre-transfer Charging PCB (PCB26) (J3545, J3500) 5. Replace the Main Driver PCB (PCB2). 6. Replace the Primary Grid High Voltage Connector (FM4- 1006).