Mã lỗi 004-0205-05 — Canon iR Advance 6555

Code: 004-0205-05

Description: Fixing Power Supply error
Causes: Detect that the Fixing Main Thermistor is not connected.
Remedy: [Related parts] - Harness between the Main Driver PCB (UN78/J104 and J105) and the Fixing Drawer Unit (J3001) (Unit of replacement: CABLE, FIXING DRAWER) - Harness between the Fixing Drawer Unit (J3001) and the Fixing Main Thermistor (THM01/J3271) (Unit of replacement: CABLE, FIXING DC DRAWER) - Fixing Main Thermistor (Unit of replacement: THERMISTOR UNIT, MAIN) - Main Driver PCB (UN78) (Unit of replacement: MAIN DRIVE DRIVER PCB ASS'Y) [Remedy] Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR.