Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 005-0000-05 — Canon iR Advance 6555

Code: 005-0000-05

Description: Fixing Cleaning Web absent error
Causes: After noticing the Fixing Cleaning Web absent, the web was pulled out 2000 times.
Remedy: Perform the following in the order while checking whether the error is cleared. 1. Replace the Fixing Cleaning Web. (Unit of replacement: CLEANER SUPPLY ROLL) 2. Replace the Fixing Cleaning Web Level Sensor (PS45). 3. Replace the DC Controller PCB (UN01). (Unit of replacement: DC CONTROLLER PCB ASS'Y) After performing the remedy work, perform the following. - Clear the counter value of the Fixing Cleaning Web (COPIER> COUNTER> MISC> FIXWEB). - Go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

← Xem tất cả mã lỗi Canon iR Advance 6555

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin