Code: 005-0001-05
Description: Error in Fixing Cleaning Web Drive Solenoid connection
Causes: Disconnection of the Fixing Cleaning Web Drive Solenoid was detected at power-on.
Remedy: [Related parts] - Harnesses from the Fixing Cleaning Web Drive Solenoid to the Fixing Drawer Unit 1. Fixing Cleaning Web Drive Solenoid (SL09/J2162) to Relay Connector (9P) to Relay Connector (9P) (Unit of replacement: CABLE, FIXING MOTOR, 1, CABLE, FIXING MOTOR) 2. Relay Connector (9P) to Fixing Drawer Unit (J3001) (Unit of replacement: CABLE, FIXING DC DRAWER) - Harness between the Main Driver PCB (UN78/J129, J104 and J105) and the Fixing Drawer Unit (J3001) (Unit of replacement: CABLE, FIXING DRAWER) - Harness between the Main Driver PCB (UN78/J108 and J101) and the Relay PCB (UN86/J522 and J515) (Unit of replacement: CABLE, SIGNAL) - Harness between the Relay PCB (UN86/J512) and the DC Power Supply PCB (24V) (J202A) (Unit of replacement: CABLE, DC 24V, A) - Harness between the Relay PCB (UN86/J513) and the DC Power Supply PCB (24V) (J202B) (Unit of replacement: CABLE, DC 24V, B) - Harness between the AC Driver PCB (UN20/J606) and the DC Power Supply PCB (24V) (J102A/ J102B) (Unit of replacement: CABLE, AC MAIN) - Harness between the AC Driver PCB (UN20/J611) and the Relay PCB (UN86/J507F) (Unit of replacement: CABLE, AC DRIVER RELAY) - Fixing Cleaning Web Drive Solenoid (SL09) - DC Power Supply PCB (24V) (Unit of replacement: 24V POWER SUPPLY ASS'Y, LEFT) - DC Power Supply PCB (24V) (Unit of replacement: 24V POWER SUPPLY ASS'Y, RIGHT) - Relay PCB (UN86) (Unit of replacement: RELAY PCB ASSEMBLY) - Main Driver PCB (UN78) (Unit of replacement: MAIN DRIVE DRIVER PCB ASS'Y) - AC Driver PCB (Unit of replacement: AC DRIVER PCB ASS'Y) [Remedy] Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR.