Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 197-0002-05 — Canon iR Advance 6555

Code: 197-0002-05

Description: Serial communication error
Causes: A communication error between the DC Controller PCB and the Feed Driver PCB was detected.
Remedy: [Related parts] - Harnesses from the DC Controller PCB to the Feed Driver PCB 1. DC Controller PCB (UN01/J421) to Relay Connector (17P) (Unit of replacement: CABLE, SIGNAL) 2. Relay Connector (17P) to Feed Driver PCB (UN79/J204) (Unit of replacement: CABLE, SERIAL) - Harness between the Feed Driver PCB (UN79/J218) and the DC-DC Converter PCB (PCB08/ J9033) (Unit of replacement: CABLE, DC) - Harness between the Feed Driver PCB (UN79/J201) and the Relay PCB (UN86/J516) (Unit of replacement: CABLE, DECK, LEFT) - Harness between the DC Controller PCB (UN01/J451) and the Relay PCB (UN86/J514) (Unit of replacement: CABLE, SIGNAL) - Feed Driver PCB (UN79) (Unit of replacement: FEED DRIVER PCB ASSEMBLY) - DC-DC Converter PCB (PCB08) (Unit of replacement: DC-DC CONVERT PCB ASS'Y) - Relay PCB (UN86) (Unit of replacement: RELAY PCB ASSEMBLY) - DC Controller PCB (UN01) (Unit of replacement: DC CONTROLLER PCB ASS'Y) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

← Xem tất cả mã lỗi Canon iR Advance 6555

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie