Code: 533-8002-02
Description: Error in the Staple-free Binding Motor (Finisher-V1)
Causes: The staple-free binding unit does not come off the Staple-free Binding HP Sensor when the Staplefree Binding Motor has been driven for 0.25 seconds.
Remedy: STAPLE FIN-V1/BOOKLET FIN-V1 [Related parts] - Harnesses from the Staple-free Binding Unit to the Finisher Controller PCB - Staple-free Binding Unit - Finisher Controller PCB (PCB101) [Points to note at work] When the Swing Guide Safety Switch (SW102) turns on at the detection timing of this error, this error code may be displayed. Accordingly, perform the following work before checking the related parts. 1. Check whether there is not the mulfunction in the swing guide unit. 2. Check whether there is not the mulfunction in the Swing Guide Safety Switch (SW102). [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] When replacing the Finisher Controller PCB, refer to "Adjustment> When Replacing the Parts" in the Service Manual.