Code: 500-0001-05
Description: Communication error
Causes: A communication error between the DC Controller PCB and the POD Deck was detected.
Remedy: [Related parts] - Harnesses from the DC Controller PCB to the Deck Driver PCB 1. DC Controller PCB (UN01/J461) to Relay Connector (9P) (Unit of replacement: CABLE, SIGNAL) 2. Relay PCB (UN86/J502) to Relay Connector (4P) (Unit of replacement: CABLE, DECK, DC) 3. Relay Connector (9P and 4P) to Deck Lattice Connector (Unit of replacement: CABLE, DECK CONNECTOR) 4. Deck Lattice Connector to Deck Driver PCB - Deck Driver PCB - DC Controller PCB (UN01) (Unit of replacement: DC CONTROLLER PCB ASS'Y) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check that the Power Supply Cable is connected to the deck/there is electrical current in the outlet/breaker of the deck is ON. 2. Check/replace the related harness/cable, connector and parts. [Reference] - After replacement of the Deck Driver PCB, refer to "Adjustments> Adjustment when Replacing the Parts" in the Service Manual. - Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES