Mã lỗi 808-0003-05 — Canon iR Advance 6555i

Code: 808-0003-05

Description: Fixing Power Supply error
Causes: Inlet current is 1 A or lower for 1 second or longer although the maximum voltage is output.
Remedy: [Related parts] - Harnesses from the Main Driver PCB to the Fixing Power Supply PCB 1. Main Driver PCB (UN78/J118 and J119) to Relay Connector (19P and 13P) (Unit of replacement: CABLE, MAIN DRIVER IH) 2. Relay Connector (19P and 13P) to Fixing Power Supply PCB (UN03/J314 and J312) (Unit of replacement: CABLE, IH SIGNAL) - Harness between the Fixing Power Supply PCB (UN03/J9904) and the Fixing Heater (CB1006 and CB1007/J9072 and J9071) (Unit of replacement: CABLE, IH DRAWER) - Fixing Power Supply PCB (UN03) (Unit of replacement: IH POWER SUPPLY PCB ASS'Y) - Fixing Heater (CB1006 and CB1007) (Unit of replacement: FIXING HEATER UNIT) - Main Driver PCB (UN78) (Unit of replacement: MAIN DRIVE DRIVER PCB ASS'Y) [Remedy] - Clean the Fixing Power Supply Cooling Fan and the Louver on right side of the host machine to remove dust. - Check/replace the related harness/cable, connector and parts.