Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 013-0002-05 — Canon iR Advance 6565

Code: 013-0002-05

Description: Waste Toner Lock detection error
Causes: The Waste Toner Lock Detection Switch detects locked while the Developing Assembly is driven.
Remedy: [Related parts] - Harness between the Main Driver PCB (UN78/J103) and the Waste Toner Lock Detection Switch (SW05/J3050) (Unit of replacement: CABLE, MAIN DRIVER RELAY) - Waste Toner Lock Detection Switch (SW05) (Unit of replacement: CABLE, LOCK DETECT SWITCH) - Main Driver PCB (UN78) (Unit of replacement: MAIN DRIVE DRIVER PCB ASS'Y) - DC Controller PCB (UN01) (Unit of replacement: DC CONTROLLER PCB ASS'Y) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check the Waste Toner Container and the Waste Toner Pipe, and remove clogged toner if there is any. 2. Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

← Xem tất cả mã lỗi Canon iR Advance 6565