Code: 068-0001-05
Description: Pre-transfer charging high voltage output leak error
Causes: The leak detection signal was detected 5 times in a row for every 20 msec.
Remedy: [Related parts] - Harness between the Main Driver PCB (UN78/J112) and the High Voltage Unit (J3098) (Unit of replacement: CABLE, MAIN, REAR UPPER) - Harness between the Relay PCB (UN86/J519) and the High Voltage Unit (J3099) (Unit of replacement: CABLE, SIGNAL) - Harnesses in the High Voltage Unit (J3098L, J3511, J3544, J3097L, J3501, J3500, J3545, J3510 and J3099M) (Unit of replacement: CABLE, HIGH VOLTAGE SIGNAL) - Pre-transfer Charging Assembly - Pre-transfer High Voltage Connector (Unit of replacement: CABLE, PRE-TRANS. CORONA H.V.) - Pre-transfer Charging PCB (Unit of replacement: PRE-TRANSFER CHARGE PCB ASS'Y) - Main Driver PCB (UN78) (Unit of replacement: MAIN DRIVE DRIVER PCB ASS'Y) [Remedy] Check/replace the related harness/cable, connector and parts.