Mã lỗi 197-0001-05 — Canon iR Advance 6565

Code: 197-0001-05

Description: Serial communication error
Causes: A communication error between the DC Controller PCB and the Main Driver PCB was detected.
Remedy: [Related parts] - Harness between the DC Controller PCB (UN01/J411, J412, J413 and J414) and the Main Driver PCB (UN78/J126, J125, J124 and J128) (Unit of replacement: CABLE, SIGNAL) - Harness between the Main Driver PCB (UN78/J101) and the Relay PCB (UN86/J515) (Unit of replacement: CABLE, SIGNAL) - Harness between the DC Controller PCB (UN01/J451) and the Relay PCB (UN86/J514) (Unit of replacement: CABLE, SIGNAL) - Main Driver PCB (UN78) (Unit of replacement: MAIN DRIVE DRIVER PCB ASS'Y) - Relay PCB (UN86) (Unit of replacement: RELAY PCB ASSEMBLY) - DC Controller PCB (UN01) (Unit of replacement: DC CONTROLLER PCB ASS'Y) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES