Mã lỗi 227-0101-04 — Canon iR Advance 6565

Code: 227-0101-04

Description: Power supply error
Causes: The DADF Driver PCB did not detect 24 V when the main power was turned ON.
Remedy: [Related parts] - Harness between the Reader Controller PCB (UN1/J111) and the DADF Driver PCB (UN03/J402) (Unit of replacement: ADF POWER CABLE) - Harnesses from the Reader Controller PCB to the Relay PCB 1. Reader Controller PCB (UN1/J101) to Relay Connector (6P) (Unit of replacement: CABLE, READER POWER SUPPLY) 2. Relay Connector (6P) to Relay PCB (UN86/J505) (Unit of replacement: CABLE, SIGNAL ) - Harness between the Relay PCB (UN86/J512) and the DC Power Supply PCB (24V) (J202A) (Unit of replacement: CABLE, DC 24V, A) - Harness between the Relay PCB (UN86/J513) and the DC Power Supply PCB (24V) (J202B) (Unit of replacement: CABLE, DC 24V, B) - Harness between the DC Power Supply PCB (24V) (J102A/J102B) and the AC Driver PCB (UN20/J606) (Unit of replacement: CABLE, AC MAIN) - Harness between the Relay PCB (UN86/J518 and J514) and the DC Controller PCB (UN01/J401 and J451) (Unit of replacement: CABLE, SIGNAL) - Reader Controller PCB (UN1) (Unit of replacement: READER CONTROLLER PCB ASSEMBLY) - DADF Driver PCB (UN03) (Unit of replacement: DF DRIVER PCB ASSEMBLY) - Relay PCB (UN86) (Unit of replacement: RELAY PCB ASSEMBLY) - DC Power Supply PCB (24V) (Unit of replacement: 24V POWER SUPPLY ASS'Y, LEFT) - DC Power Supply PCB (24V) (Unit of replacement: 24V POWER SUPPLY ASS'Y, RIGHT) - AC Driver PCB (UN20) (Unit of replacement: AC DRIVER PCB ASS'Y) - DC Controller PCB (UN2) (Unit of replacement: DC CONTROLLER PCB ASS'Y) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - When an error is detected, conduction of 24 V is stopped. At power check, check if 24 V is conducted or rated voltage is output by repeating power cycling of the machine. - Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES - Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

← Xem tất cả mã lỗi Canon iR Advance 6565

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie