Mã lỗi 5F1-8003-02 — Canon iR Advance 6565

Code: 5F1-8003-02

Description: Saddle Delivery Motor clock error (Finisher-V1)
Causes: The lock state of Saddle Delivery Motor is detected 0.2 seconds or more while the motor operates.
Remedy: STAPLE FIN-V1/BOOKLET FIN-V1 [Related parts] - Harnesses from the Saddle Delivery Motor Clock Sensor (PS211) to the Saddle Stitcher Controller PCB - Harnesses from the Saddle Delivery Motor (M207) to the Saddle Stitcher Controller PCB - Saddle Delivery Motor Clock Sensor (PS211) - Saddle Delivery Motor (M207) - Saddle Stitcher Controller PCB (PCB201) - Finisher Controller PCB (PCB101) [Points to note at work] When the Swing Guide Safety Switch (SW102) turns on at the detection timing of this error, this error code may be displayed. Accordingly, perform the following work before checking the related parts. 1. Check whether there is not the mulfunction in the swing guide unit. 2. Check whether there is not the mulfunction in the Swing Guide Safety Switch (SW102). [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] When replacing the Finisher Controller PCB, refer to "Adjustment> When Replacing the Parts" in the Service Manual.