Code: 732-0010-00
Description: Scanner communication error
Causes: A signal to start image transfer could not be detected at scanning although the specified period of time (120 sec) has passed.
Remedy: [Related parts] - Harness between the Reader Controller PCB (UN1/J109) and the Main Controller PCB 2 (PWB02/J4031) (Unit of replacement: CABLE, INTERFACE) - Main Controller PCB 2 (PWB02) (Unit of replacement: MAIN CONTROLLER PCB ASS'Y, 2) - Main Controller PCB 1 (PWB01) (Unit of replacement: MAIN CONTROLLER PCB ASS'Y, 1) - Reader Controller PCB (UN1) (Unit of replacement: READER CONTROLLER PCB ASSEMBLY) [Points to note at work] After performing the remedy, check that the copy image is output normally. [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Reinstall the latest system software using SST or a USB memory. 2. Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES