Mã lỗi 808-0001-05 — Canon iR Advance 6565

Code: 808-0001-05

Description: Fixing Power Supply error
Causes: Overvoltage was detected at power-on. - 145 V or higher for 100V/120V machine - 290 V or higher for 230V machine
Remedy: [Related parts] - Harnesses from the Main Driver PCB to the Fixing Power Supply PCB 1. Main Driver PCB (UN78/J118 and J119) to Relay Connector (19P and 13P) (Unit of replacement: CABLE, MAIN DRIVER IH) 2. Relay Connector (19P and 13P) to Fixing Power Supply PCB (UN03/J314 and J312) (Unit of replacement: CABLE, IH SIGNAL) - Harnesses from the AC Driver PCB to the Fixing Power Supply PCB 1. AC Driver PCB (UN20/J601) to Relay Connector (2P) (Unit of replacement: CABLE, AC-IH) 2. Relay Connector (2P) to Fixing Power Supply PCB (UN03/J2401) (Unit of replacement: CABLE, AC MAIN BODY) - Fixing Power Supply PCB (UN03) (Unit of replacement: IH POWER SUPPLY PCB ASS'Y) - Main Driver PCB (UN78) (Unit of replacement: MAIN DRIVE DRIVER PCB ASS'Y) [Remedy] - Check the voltage of the outlet, and connect the machine to the correct outlet if it is wrong. - Check/replace the related harness/cable, connector and parts.