Code: 808-0005-05
Description: Fixing Power Supply error
Causes: Detected OFF with output 12 V of the Fixing Power Supply after IH relay is turned ON.
Remedy: [Related parts] - Harnesses from the Main Driver PCB to the Fixing Thermoswitch 1. Main Driver PCB (UN78/J129) to Relay Connector (3P) to Fixing Drawer Unit (J3001) (Unit of replacement: CABLE, FIXING DRAWER) 2. Fixing Drawer Unit (J3200) to Fixing Thermoswitch (TP01 and TP02) (Unit of replacement: CABLE, FIXING DC DRAWER) - Harnesses from the Main Driver PCB to the Fixing Power Supply PCB 1. Main Driver PCB (UN78/J118 and J119) to Relay Connector (19P and 13P) (Unit of replacement: CABLE, MAIN DRIVER IH) 2. Relay Connector (19P and 13P) to Fixing Power Supply PCB (UN03/J314 and J312) (Unit of replacement: CABLE, IH SIGNAL) - Fixing Power Supply PCB (UN03) (Unit of replacement: IH POWER SUPPLY PCB ASS'Y) - Main Driver PCB (UN78) (Unit of replacement: MAIN DRIVE DRIVER PCB ASS'Y) - Fixing Thermoswitch (TP01 and TP02) (Unit of replacement: THERMOSWITCH) [Remedy] Check/replace the related harness/cable, connector and parts.