Code: 061-0001-05
Description: Potential control error (VL)
Causes: The dark area potential (VL) failed to be 200 V or less at potential control.
Remedy: [Related parts] - Harnesses from the Main Driver PCB to the Pre-exposure LED 1. Main Driver PCB (UN78/J107) to Relay Connector (12P) (Unit of replacement: CABLE, MAIN, REAR UPPER) 2. Relay Connector (12P) to Relay Connector (20P) (Unit of replacement: CABLE, AP. KIT DRAWER) 3. Relay Connector (20P) to Pre-exposure LED (LE01/J2141) (Unit of replacement: DRAWER ASSEMBLY) - Harnesses from the Main Driver PCB to the Primary Charging High Voltage PCB 1. Main Driver PCB (UN78/J111) to Relay Connector (9P) (Unit of replacement: CABLE, MAIN, REAR UPPER) 2. Relay Connector (9P) to Primary Charging High Voltage PCB (J3501) (Unit of replacement: HIGH VOLTAGE PCB ASS'Y) - Harnesses from the Main Driver PCB to the Potential Sensor 1. Main Driver PCB (UN78/J114) to Relay Connector (31P) (Unit of replacement: CABLE, MAIN DRIVER, REAR UPPER) 2. Relay Connector (31P) to Relay Connector (25P) (Unit of replacement: CABLE, RELAY, FRONT) 3. Relay Connector (25P) to Relay Connector (7P) (Unit of replacement: CABLE, MAIN DRIVER, FRONT) 4. Relay Connector (7P) to Potential Sensor (EPC01/J5014) (Unit of replacement: CABLE, POTENTIAL SENSOR) - Harness between the Main Driver PCB (UN78/J109) and the Drum Motor (M01/J2138) (Unit of replacement: CABLE, MAIN, REAR UPPER) - Primary Charging Assembly - Laser Scanner Unit - Potential Sensor (EPC01) (Unit of replacement: POTENTIAL MEASURING PCB ASS'Y) - Primary Charging High Voltage PCB (Unit of replacement: HIGH VOLTAGE PCB ASS'Y) - Drum Motor (M01) - Pre-exposure LED (LE01) - Main Driver PCB (UN78) (Unit of replacement: MAIN DRIVE DRIVER PCB ASS'Y) - DC Controller PCB (UN01) (Unit of replacement: DC CONTROLLER PCB ASS'Y) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES