Mã lỗi 065-0001-05 — Canon iR Advance 6565i

Code: 065-0001-05

Description: Primary charging/grid high voltage output leak error
Causes: The leak detection signal was detected 5 times in a row for every 20 msec.
Remedy: [Related parts] - Harness between the Main Driver PCB (UN78/J111) and the High Voltage Unit (J3097) (Unit of replacement: CABLE, MAIN, REAR UPPER) - Harness between the Relay PCB (UN86/J519) and the High Voltage Unit (J3099) (Unit of replacement: CABLE, SIGNAL) - Harnesses in the High Voltage Unit (J3098L, J3511, J3544, J3097L, J3501, J3500, J3545, J3510 and J3099M) (Unit of replacement: CABLE, HIGH VOLTAGE SIGNAL) - Primary Grid High Voltage Connector (Unit of replacement: DRUM DRIVE ASS'Y) - Primary Charging High Voltage PCB (Unit of replacement: HIGH VOLTAGE PCB ASS'Y) - Main Driver PCB (UN78) (Unit of replacement: MAIN DRIVE DRIVER PCB ASS'Y) [Remedy] Check/replace the related harness/cable, connector and parts.