Code: 280-0101-04
Description: Communication error
Causes: Communication between the Reader Controller PCB and the DADF Scanner Unit was not completed within the specified period of time.
Remedy: [Related parts] - Harness between the DADF Scanner Unit (J1102) and the Reader Controller PCB (UN1/J105) (Unit of replacement: FLEXIBLE FLAT CABLE UNIT) - Harness between the Reader Controller PCB (UN1/J109) and the Main Controller PCB 2 (PWB02/J4031) (Unit of replacement: CABLE, INTERFACE) - DADF Scanner Unit (Unit of replacement: SCANNER UNIT, ADF) - Reader Controller PCB (UN1) (Unit of replacement: READER CONTROLLER PCB ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES