Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 824-0000-05 — Canon iR Advance 6565i

Code: 824-0000-05

Description: Primary Charging Air Supply Fan error
Causes: The Fan stop signal is detected for 5 seconds or longer and retry is failed 4 times in a row although the Primary Charging Air Supply Fan is turned ON.
Remedy: [Related parts] - Harnesses from the Main Driver PCB to the Primary Charging Air Supply Fan 1. Main Driver PCB (UN78/J130) to Relay Connector (17P) (Unit of replacement: CABLE, MAIN DRIVER, REAR UPPER) 2. Relay Harness (17P) (Unit of replacement: CABLE, RELAY, FRONT, CABLE, MAIN DRIVER, FRONT) 3. Relay Connector (17P) to Primary Charging Air Supply Fan (FM02/J2131) (Unit of replacement: CABLE, FAN) - Primary Charging Air Supply Fan (FM02) - Main Driver PCB (UN78) (Unit of replacement: MAIN DRIVE DRIVER PCB ASS'Y) [Remedy] Check/replace the related harness/cable, connector and parts.